Minnesota-based project supportResidential + commercial(612) 270-8121

Aluminum window and door frame profiles.

Frame depth, visible aluminum, thermal separation, glazing pocket, sill, tracks, and hardware all change with the profile family.

65-239 mmPlatform-depth directions20-64 mmVisible-width references

Four dimensions shape the opening.

A deeper profile is not automatically better, and a slimmer profile is not automatically weaker. The right choice depends on operation, panel size, glass, exposure, sill strategy, hardware, and the documentation required for the project.

Profile depth

The overall front-to-back frame dimension. Deeper profiles may support larger insulating zones, glazing pockets, tracks, reinforcement, or multi-panel movement.

Visible sightline

The aluminum seen around the glass or where panels meet. A narrower sightline increases the glass-to-frame ratio, but it does not by itself define performance.

Thermal break

An insulating barrier separating interior and exterior aluminum. Its design works with glass, spacers, seals, size, and installation to shape whole-unit performance.

Sill + track geometry

The bottom profile manages movement, drainage, weather seals, accessibility, and screen coordination. Low-profile and higher-weathering directions involve tradeoffs.

Compare the platform before choosing the finish.

These references organize the available directions without turning a catalog number into a performance promise. Final dimensions and documentation are confirmed for the exact unit.

Thermal windows01

65 Thermal Window Profile

A balanced thermally broken platform for clean residential casement, awning, fixed, and combination window elevations.

Profile depth
65 mm
Visible reference
Approx. 30 mm
Glass reference
Up to 48 mm reference
Thermal direction
24 mm thermal barrier
  • Casement + awning windows
  • Fixed and operable combinations
  • Balanced depth and sightline
View related product
Enhanced thermal windows02

80 Deep Thermal Window Profile

A deeper window platform with a wider insulating zone and additional glazing capacity for more demanding project goals.

Profile depth
Approx. 80 mm
Visible reference
Approx. 30 mm
Glass reference
Up to 61 mm reference
Thermal direction
39 mm thermal barrier
  • Thermal design priorities
  • Thicker insulating glass
  • Casement, awning + fixed units
View related product
Thermal swing doors03

80 Thermal Hinged Door Profile

A substantial hinged-door platform for inward or outward swing, multi-point locking, and project-specific threshold conditions.

Profile depth
80 mm
Visible reference
Approx. 50 mm
Glass reference
Up to 48 mm reference
Thermal direction
Thermally broken platform
  • Single and French doors
  • Low- or high-threshold layouts
  • Glazed door and sidelite packages
View related product
Minimal sliding doors04

146 Slim Sliding Profile

A minimal sliding platform that reduces the vertical interlock and emphasizes uninterrupted glass across large openings.

Profile depth
146 mm platform
Visible reference
Approx. 20 mm interlock
Glass reference
By panel engineering
Thermal direction
High glass-to-frame ratio
  • Minimal architectural sightlines
  • Large view openings
  • Concealed-roller sliding layouts
View related product
Thermal folding doors05

75 Thermal Folding Profile

A folding-door profile that balances narrow panel stiles with the hinge strength, glazing depth, and sill choices needed for multi-leaf openings.

Profile depth
75 mm
Visible reference
Approx. 36 mm
Glass reference
Up to 51 mm reference
Thermal direction
Thermally broken platform
  • Two- to eight-leaf layouts
  • Left, right, or split stacks
  • Low- and standard-sill options
View related product
Thermal lift + slide06

153 Lift + Slide Profile

A thermal lift-slide platform for oversized glass panels, secure compression sealing, and lower-sill design directions.

Profile depth
153 mm
Visible reference
Approx. 64 mm
Glass reference
Up to 53 mm reference
Thermal direction
Thermally broken platform
  • Large two-panel openings
  • Sliding + fixed combinations
  • Premium residential glass walls
View related product
Deep multi-track lift + slide07

239 Multi-Track Lift + Slide Profile

A deeper lift-slide platform that creates room for multi-track stacking arrangements while retaining the same refined vertical sightline direction.

Profile depth
239 mm
Visible reference
Approx. 64 mm
Glass reference
Up to 53 mm reference
Thermal direction
Thermally broken platform
  • Multi-track stackers
  • Broad clear-opening goals
  • Large-format panel packages
View related product
Commercial profiles08

100-150 Commercial Platforms

Operation-specific commercial profiles for awning windows, hinged entrances, sliders, stackers, louvers, and folding doors.

Profile depth
100-150 mm range
Visible reference
Approx. 25-50 mm
Glass reference
Varies by operation
Thermal direction
Standard or project-specific
  • Retail and hospitality openings
  • High-use entrances
  • Operation-specific commercial detailing
View related product

Profile depths, visible widths, thermal-barrier dimensions, and glazing capacities are general platform references. They are not rough-opening dimensions, glass-edge dimensions, whole-unit ratings, or guaranteed limits. Final configuration, drawings, performance documentation, sill, hardware, and availability are confirmed for each project.

Compare performance using verified numbers.

Selected available configurations have current North American directory and approval evidence. The fair comparison is product to product: matching operator type, size, glass, test method, and installation basis.

0.13

U-factor

Select thermally broken configurations can reach U-factors as low as 0.13. The exact whole-unit value is confirmed for the quoted configuration.

±55 psf

Florida design pressure

A selected impact-resistant horizontal slider is approved for both HVHZ and non-HVHZ use at +55/-55 psf.

NFRC + NAFS

North American framework

Thermal values and fenestration performance are evaluated through the same North American standards used for premium U.S. systems.

These are configuration-specific examples, not blanket ratings for every profile. BelleVier matches the applicable label, approval, test report, glass, operator type, size, anchorage, and installation requirements to the quoted unit before a value becomes a project claim.

Choose the operation first. Then match the profile.

  1. 01
    Define movement

    Fixed, swing, slide, lift-slide, fold, or automatic operation.

  2. 02
    Set the visual goal

    Sightline, panel rhythm, glass area, finish, and interior/exterior alignment.

  3. 03
    Name the performance needs

    Thermal, air, water, structural, acoustical, safety, or accessibility criteria.

  4. 04
    Confirm the exact package

    Profile, glass, sill, hardware, reinforcement, drawings, and project-specific documents.

Review my openings

Send the opening, not just a profile number.

A clear opening schedule makes the comparison useful. Start with these four groups of information and label any assumptions that need confirmation.

Opening schedule

Give each opening an ID, quantity, and dimensions. Label what was measured: the existing frame, the rough opening, or a proposed unit. Include units and mark dimensions that still need site verification.

Operation and access

Identify fixed, tilt-turn, casement, sliding, lift-slide, or folding operation. Show the preferred opening direction, adjacent walls, and any access questions the project team needs to resolve.

Drawings and appearance

Send elevations or photos, your preferred panel arrangement, finish direction, and the interior and exterior views. Mark any sightline or alignment that matters to the design.

Project requirements

Include the project city and state, desired timing, applicable performance criteria supplied by your project team, and who will coordinate installation. Keep undecided items clearly marked.

Before comparing ratings, use the window quote and performance-document checklist. For the broader selection, compare window and door systems and glass, finish, and hardware options.

Answers before the project review.

Which aluminum window profile should I choose?

Begin with the opening and operating style, then compare suitable profile families. Send the dimensions, glass direction, appearance goals, and project requirements so the proposed package can be reviewed together.

Is profile depth the same as a rough-opening size?

No. The depth figures on this page describe profile platforms. Label your opening measurements separately and confirm the ordered unit, rough opening, and installation details on the project drawings before ordering.

Can I use one brochure rating for every window and door?

Ask for the documentation applicable to each quoted configuration. This page's selected performance examples should not be transferred to another size, operating style, glazing package, or profile without supporting evidence.

Can I request a review before every detail is decided?

Yes. Send the plans, photos, or early design direction you have and identify what is still undecided. The first review can organize the open questions; final dimensions, configuration, documents, and scope must be confirmed before ordering.

Send plans or photos for a profile review

Let's make the opening work.

Send a plan set, rough opening list, or even an early concept. We'll help identify the right next step.

Request a project review